Medical Instruments

SP-3000 UV-VIS Spectrophotometer

Operating Mode

  • Fixed wavelength Mode
    1.Measurement at a user-selected fixed wavelength.
    2.Quantitation using the K-factor method
    3.Photometric mode: Choice of %T and Abs.
  • Survey scan Mode
    1.Automatic Peak and Valley Pick.
    2.Addition and Subtraction
    3.Spectrum Overlay
    4.Zoom.
    5.Trace.
    6.Spectral storage
  • Standard Mode
    1. 1st ~ 4th derivative methods.
    2. Automatic concentration calculation by K-factor, single-point calibration curve.
    3.Curve fitting and editing.
    4.Method Storage
  • Kinetics Mode
    1.Reaction rate calculation and recalculation.
    2.Tabulation of results
    3.Export of time-course data via RS-232C port
  • Multicomponent Mode
    1.Up to 8 components can be simultaneously quantitated.
    2.Arithmetic calculation between a value.
    3.Up to 8cell and Multiwavelengths combination.
  • DNA/Protein Mode
    1.260/280nm, 280/260nm ratio or two user selected wavelengths
    2.Correct background at 320nm

Specifications

Wavelength Range

190 ~ 1100nm

Spectral Bandwidth

1nm

Wavelength Display

Readable to 0.1nm

Wavelength Accuracy

กพ0.2nm (with automatic wavelength correction)

Data Bunching Interval

0.1, 0.2, 0.3, 0.4, 0.5, 0.6, 0.7, 0.8, 0.9, 1.0 and 2.0nm

Wavelength Reproducibility

กพ0.1nm

Stray Light

Less than 0.05% (at 220nm and 340nm)

Photometric Range

Absorbance : -0.3 ~ 4Abs

Photometric System

Split-beam optics, Dual detectors

Photometric Accuracy

กพ0.002Abs. at 0.5Abs. กพ0.005Abs. at 1Abs.

Photometric Reproducibility

กพ0.002Abs. at 1.0Abs.

Baseline Flatness

กพ0.001Abs (2nm bandwidth, middle scanning, 1100 ~ 200nm)

Baseline Correction

Automatic

Wavelength Slew Rate

About 4000nm/min

Light Source

50W halogen lamp (1000 hrs life) and D2 lamp (2000 hrs life)

Monochromator

An aberration reduced holographic concave grating using 1200L/mm

Auto Zero Function

By a single stroke of AUTO ZERO key

Display Graphic

LCD 6", adjustable viewing angle and contrast control

Sample Compartment

Automatic rotative 8 position cell holder

Interface Ports

RS-232C and Centronics ports

Power Requirements

85~260V~, 50/60Hz, Selected automatically

Dimensions

550(W) X 240(H) X 400(D)mm

Weight

25kg

Optional Accessories

Number

Description.

30001

Printer

30002

Film Holder

30003

Flow-thru Cell System

30004

Temperature Control Module

30005

Standard Quartz Cell

30006

500 Micro Quartz Cell

30007

1000 Micro Quartz Cell

Continuing research and improvements may result in specifications change at any time.

 